VINYL CHLORIDE inhibited or stabilized
https://midsis.rempec.org/en/find-chemical/vinyl-chloride-inhibited-or-stabilized
https://midsis.rempec.org/@@site-logo/logo_rempec_128x117.png
VINYL CHLORIDE inhibited or stabilized
UN Number: 1086
Also known as:
CHLORETHENE, CHLOROETHYLENE, CHLORURE DE VINYLE stabilisé
Information on chemical
Information on chemical
External resources
CAMEO Chemical Database
WISER Substance List
Description
Physical chemical data
Physical State (20°C)
Gas
Density (kg/m3)
2.786 [Kg/m³]
at a temperature of
20°C
Molar mass (g/mol)
62.5
Density of gas (kg/m3)
2.786
Boiling Point (°C)
-13.6
Melting Point (°C)
-154
Vapour Pressure (Pa)
340000 [Pa]
at a temperature of
20°C
Ignition Temperature (°C)
473
Flash Point (°C)
-77
Lower explosivity limit (LEL) (volume %)
3.6
Upper explosivity limit (UEL) (volume %)
33
Additional data
Colour
colourless
Odour
pleasant, fruit odour
Standard behavior classification
GD, G
Transportation data
Transport mode
Gas,Packaged
Ship type
2G,2PG
Cargo group
35
State
liquefied gas
Temperature (°C)
ambient
Pressure (Pa)
ambient
Family name
vinyl halides
IMO class
2(2.1)
Reactivity data
Water
No
Acid(s)
Yes
Base(s)
No
Metal(s) and alloys
No
Static electricity
Yes
Oxidizing agents
Yes
Reducing agents
No
Combustibles
No
Organic substance
No
Human toxicity threshold
ERPG-1 (ppm)
500
ERPG-2 (ppm)
5000
ERPG-3 (ppm)
20000
Incident reports
Incident reports
Year
Vessel
Location
Cargo type
1984
Brigitta Montanari
Off Croatian Coast
Bulk
Emergency Response Guidebook
At sea emergency guide
At sea emergency guide
Emergency schedule: 2-07
LIQUEFIED GASES, FLAMMABLE.
Emergency procedures
Action
Avoid all skin contact.
Avoid all sources of ignition (e.g. naked lights, unprotected light bulbs, electric handtools).
Spillage on deck
Stop leak if practicable. Let spilt liquid evaporate.
Spillage under deck
Provide adequate ventilation. Stop leak if practicable. Let spilt liquid evaporate.
Fire on deck
Use water spray, foam or dry chemical from as far away as practicable.
Keep adjacent receptacles cool with copious quantities of water. Remove undamaged cooled receptacles to a safe place.
Fire under deck
Batten down; use ship's fixed fire-fighting installation. Otherwise adopt action as for "On deck".
Special equipment to be carried
Protective gloves.
Self-contained breathing apparatus.
Spray nozzles.
Remarks by UN no.
ACETYLENE, DISSOLVED (UN No. 1001)
Care! Heated receptacles should be jettisoned as possible explosion hazard.
Decision trees
Decision trees
No decision trees available
No additional data