3-03
1 CLASS 3.1
FLAMMABLE LIQUIDS, FLASHPOINT BELOW -18°C Closed Cup., TOXIC AND/OR CORROSIVE; IMMISCIBLE WITH WATER
2 CLASS 3.2
FLAMMABLE LIQUIDS, FLASHPOINT BETWEEN -18°C AND 23°C Closed Cup., TOXIC AND/OR CORROSIVE; IMMISCIBLE WITH WATER
3 CLASS 3.3
FLAMMABLE LIQUIDS, FLASHPOINT BETWEEN 23°C AND 61°C Closed Cup., TOXIC AND/OR CORROSIVE; IMMISCIBLE WITH WATER
Emergency procedures
Action
Avoid all sources of ignition (e.g. naked lights, unprotected light bulbs, electric handtools).
Turn ship off-wind.
Spillage on deck
Wash spillage overboard with copious quantities of water.
Spillage under deck
Provide adequate ventilation. Collect spillage, where practicable, using absorbent material, for safe disposal.
Fire on deck
Use water spray, foam or dry chemical. Do NOT use water jet. If possible remove receptacles likely to be involved or keep them cool with copious quantities of water.
Fire under deck
Batten down; use ship's fixed fire-fighting installation. Otherwise adopt action as for "On deck".
Special equipment to be carried
Protective clothing (gloves, boots, coveralls, headgear).
Self-contained breathing apparatus.
Spray nozzles.